adminandClaude Opus 5.5 01ee61868b Show a Gain node as an orange device with one knob (#384)
A Gain node now draws a small device in the graph, as the Compressor
does since #380: the brushed plate in orange, 160x220 graph units, with
one chrome knob between its inputs and its output.

- GainPanel and GainFace join the node faces. The knob drags, resets
  on a double-click and keeps the wheel for the graph (#383). Each turn
  is one undo step, a linked Gain (dB) greys it.
- The knob turns with a taper of 0.26, so 0 dB stands straight up and
  the range below -24 dB takes a fifth of the turn.
- drawPlate, engrave and the brushed look move out of CompressorPanel
  so both devices share them. The Knob takes an arc colour, because
  the orange arc vanished on the orange plate.
- No meter and no tap. Gain sits in every voice of an instrument, and
  a tap would add two audio nodes to each note for a display nobody
  asked for.

Found on the way:
- Knob.dialGlobal added half the dial unscaled. In a zoomed graph it
  pointed beside the dial. The Compressor's e2e only hit by luck.

Tests:
- Unit: 2 new for the Gain plate and its taper.
- e2e 34 on atx: ALL PASSED, 126 checks (1 new).
- Gate on atx: CHECK EXIT 0, 283 files, 4359 tests.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-10 13:07:44 +02:00
adminandClaude Opus 5.5 79a04e6764 Edit a Parametric EQ in its node, let the wheel only zoom graphs (#381)
The small curve below the EQ node's rows (#375) only showed the bands.
Like the Compressor since #380, the node now shows the editor of its
tab between its inputs and its output, and is worked right there. A
double-click on the node still opens the same editor in a tab.

Two wishes for the nodes with a panel came on top and share the same
files, so they are in this commit as well: the numbers below the
Compressor's knobs read as plain labels (#382), and the wheel over a
node zooms the graph instead of turning a value (#383).

#381, the EQ in its node:
- EqPanel holds the curve, the band's numbers and the help line, taken
  out of EqEditor. The tab puts its one panel under a header, each EQ
  node has a panel of its own at 720 x 360 (EqFace).
- A press on the curve neither picks nor moves the node. A
  double-click on the curve adds a band, one on the title or the edge
  opens the tab.
- In the node a press on the Type or Slope button stays with the
  button, so the node is not picked or moved.
- The spectrum runs in the node while it is in the picture. The tab
  lets go of the tap once, like the Compressor's, and Editor.tick lets
  every unseen tab and graph go before any seen one listens.
- The count of bands moved from the tab's header into the band row,
  so the node shows it as well.
- The node picture of #375 is gone with its only user: NodePicture,
  EQ_PICTURE and NodeView's drawing of it.

#382, the numbers below the Compressor's knobs in its node:
- A Knob with typed: false shows its number as a centred Label without
  a box, in the panel's ink. The ratio reads 4:1 (ratioText).
- The label is as high as its text and sits up in the dial's open
  bottom, right under the ends of the scale.
- Label takes a colour of its own.

#383, the wheel in a graph:
- GraphCanvas takes the wheel on the way down and stops it there. It
  zooms over a node too, and no knob or curve in a node sees it.
- The tabs keep their wheel: a knob's step, a band's Q and the zoom
  of the EQ's dB.

Found on the way:
- A Menu opened below a button in the zoomed graph would have been
  placed by the button's own height. openBelow now takes the bottom
  edge as drawn.
- The band row did not lay out its labels after a text change when
  its own size stayed. In the tab a later resize hid it, in the node
  "Band 1" and the count were missing. The row now lays out itself.
- Handle and point positions for the checks were unscaled. They now
  go through toGlobal and hold at the graph's zoom.

Tests:
- Unit parametric-eq: 16 tests. The #375 tests now check
  eqCurvePoints and eqRangeOf directly. compressor-view: ratioText.
- e2e 34 (atx): ALL PASSED, 125 checks (3 new: the EQ panel and its
  ports, editing in the node, the spectrum in the node with the tab
  open). The Compressor node's check reads its numbers as labels and
  8:1. Both node checks now expect the wheel to zoom the graph and
  leave the ratio, the Q and the dB zoom alone.
- The unseen-tab check now leaves for the Scene tab, since the node
  in the graph listens to the same tap.
- Counter-check: the tab letting go of the tap every unseen frame
  stalls the node's spectrum with the tab open (1 frame against 22,
  probe on stein2).
- Gate (atx): CHECK EXIT 0, 283 files, 4357 tests.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-10 12:40:11 +02:00
adminandClaude Opus 5.5 1f2b64fb4c Show a Compressor's panel in its node, its tab on a double-click (#380)
game-maker / gate (push) Successful in 4m2s
game-maker / suite (push) Successful in 16m14s
The panel of #379 opened in a window of its own and replaced the tab.
The user wanted the device in the graph instead, and the tab of #378
back on a double-click. The switch Hardware look goes again.

- A node can show a face instead of its rows (`NodeFace`). Its inputs
  sit on the left of it and its outputs on the right, in the middle of
  the height. Each side is as wide as its longest port name.
- A Compressor node shows the panel at full size, 820x280 graph units.
  Its settings and numbers are not listed as rows, the panel has them.
- The knobs and the lever work in the node. A drag, a notch of the
  wheel and a double-click are one undo step each. A press on them
  neither picks nor moves the node, and the wheel does not zoom the
  graph. The number below a knob is only shown, typing stays in the
  tab and the inspector.
- The meter and the LEDs run while the node is in the picture of a sound
  FX or instrument graph that is seen. Out of the picture, folded or
  hidden, the node lets go of its taps.
- The window of one size, `fixedSize`, `refit`, `keptSize` and the rule
  that kept a Compressor out of the tab row are gone again.
- A knob's drag as one undo step lives in `nodeParamDrag.ts` now, for
  the tab and the node. The numbers of a node and what auto-gain says
  moved to `compressorView.ts`.

Found and fixed on the way:
- The tab and the node listen to the same taps. The tab let go of them
  on every frame it was not seen, so the node's meter stood still while
  the tab was open. Now the tab lets go once, and in a frame everything
  unseen lets go before anything seen listens.

Tests:
- Unit: compressor-view (2 new), documents (the test of `keptSize` is
  gone with it)
- e2e 34 (stein2, melektaus-atx was off): ALL PASSED, 122 checks. The
  four checks of #379 are now four of the node: ports beside the panel,
  knobs and lever in the node, the needle when played (21.7 dB with the
  tab open), and the double-click opening the tab.
- Gate (stein2): CHECK EXIT 0, 283 files, 4356 tests
- Counter-checks: an old auto-gain number read as off turns exactly its
  unit test red. A tab that lets go on every frame leaves the node's
  needle at 0 dB and no LED lit (probe on stein2).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>